Device layer or abstraction layer?

IvoryOS reads whatever class you give it. The question is which class: the vendor’s SDK object with its forty methods, or a short class of your own that says what the instrument does on your bench. Both work. They make very different apps.

What the scientist sees is the method list

Section titled “What the scientist sees is the method list”

Every public method is a step in the Designer’s toolbox and a form on the Instruments page. A raw SDK gives:

pump.write_register(addr, value) pump.read_register(addr) pump.set_mode(0x02)
pump.start() pump.stop() pump.get_status() pump.flush_buffer() ...

A class written for the bench gives:

pump.dispense(volume_ml, flow_rate_ml_min=2.0) pump.prime(cycles=3) pump.refill()

The second is what a workflow reads like, what the assistant can reason about, and what a colleague can run without the manual. So the guidance is simple:

Expose what a person would say at the bench. One method is one action that completes: dispense 2 mL, hold 30 minutes, weigh. Arguments are in the units the lab uses, and the return value is the measurement, as a number or an object with numbers in it.

  • The SDK already speaks that language (pump.dispense(volume=…)). Use it directly.
  • You are characterising a new instrument and want every knob on the Instruments page for a while. Put the SDK object on the deck as its own instrument, and keep it there until the real methods are clear.
  • The vendor class is a thin wrapper over a well-designed protocol, and the extra forty methods do not get in the way.
  • The SDK exposes registers, modes, buffers or state machines.
  • An action takes several SDK calls in a fixed order (set mode, start, wait, read, stop).
  • The SDK’s units are not the lab’s (steps instead of mL, raw counts instead of mg).
  • The vendor class inherits many methods you do not want shown (every method of a base class is a step, including a modelling library’s).
  • You want a limit that lives in code, such as a maximum temperature the hardware cannot be trusted to refuse. (Limits that may change per bench belong on the Safety page instead; see below.)

Write it by composition, not inheritance: keep the vendor object in a private attribute and expose your own methods. Inheriting would publish the whole base class.

class Reactor:
"""Heated stirrer block, one vial."""
def __init__(self, port: str, max_temperature_c: float = 150.0):
self._dev = VendorHotplate(port) # the device layer, hidden
self.max_temperature_c = max_temperature_c
def set_temperature(self, setpoint_c: float) -> dict:
"""Set the block setpoint and wait until it is reached."""
if setpoint_c > self.max_temperature_c:
raise ValueError(f"{setpoint_c} C exceeds the block limit of {self.max_temperature_c} C")
self._dev.write_setpoint(setpoint_c)
self._dev.wait_stable(tolerance=0.5)
return {"setpoint_c": setpoint_c, "reached_c": self._dev.read_temperature()}
def hold(self, minutes: float) -> dict:
"""Hold at the current setpoint. Blocks for the whole hold."""
time.sleep(minutes * 60)
return {"minutes": minutes}
@property
def temperature(self) -> float:
return self._dev.read_temperature()

You do not have to choose for the whole deck. Common shapes:

  • Abstraction on the deck, device layer reachable by hand. Put the vendor object on the deck too, under a name like reactor_raw. Workflows use reactor; the Instruments page still has every SDK call for troubleshooting. Nothing stops a workflow from using the raw one, so this suits a lab that trusts its users; the Safety page can add rules around either.
  • Hide the dangerous half. Keep the SDK methods on your class but prefix the ones nobody should call from a workflow with _. They stay available to your own code.
  • One method that runs a whole sequence. A run_calibration() that does ten things inside is fine: it is one step the scientist can reason about. Declare what must hold before it and what it leaves behind on the Safety page (a rule and a state), since the guard cannot see inside it.

Resist the urge to put every bound in the driver. A bound that comes from the hardware (the block cannot exceed 150 °C) belongs in code, as above, because it is true on every bench. A bound that comes from this experiment or this lab (today’s vials tolerate 120 °C; this pump never dispenses more than 5 mL into a 10 mL vial) belongs on the Safety page: it is checked before a run starts and before each call, outside the driver, and survives a driver update. Nothing is asked of the driver for that. See Safeguards.

The same goes for units and labels: the Safety page attaches a unit to a field without the driver changing, and the Instruments, Run and Data History pages show it everywhere. A driver may declare one (Annotated[float, Unit("°C")]) when it describes what the code really does.